Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Rev. bras. cir. cardiovasc ; 31(2): 178-182, Mar.-Apr. 2016. tab
Artigo em Inglês | LILACS | ID: lil-792654

RESUMO

Abstract Introduction: To obtain the optimal anesthesia depth is not easy in cardiovascular surgery patients where the haemodynamic reserve is limited, due to reasons such as not being able to give the desired dose of anesthetic agent, or the change in the pharmacokinetics of the agent in the heart-lung machine. This study was planned to assess the contribution of bispectral index (BIS) monitoring in the depth of anesthesia. Methods: The patients were divided into 2 groups, and BIS monitoring was used for each patient. Group 1 (G1 n=35): keeping the BIS monitor screen open, the anesthesia need was set. Group 2 (G2 n=35): BIS monitor was tied to the patient and the monitor screen was closed in such a way that the anaesthesist couldn't see the BIS value. When the recording time came, the data on the monitor was recorded. The need for the anesthetic agent was set according to the parameters such as haemodynamics or follow up of pupils, instead of BIS value, by titrating the anesthetic infusion doses. Results: BIS values were similar in both groups before the induction, BIS values in both groups showed a decrease, showing no significant statistical difference (P>0.05). One patient in each group said that he dreamt, and one patient in G2 said that he had heard a noise and felt that he was taken from one place to another. Conclusion: The management should be done with clinical evaluation, haemodynamics and other monitorization methods and BIS monitoring findings together.


Assuntos
Humanos , Pessoa de Meia-Idade , Idoso , Ponte de Artéria Coronária/instrumentação , Monitorização Intraoperatória/métodos , Monitores de Consciência/estatística & dados numéricos , Consciência no Peroperatório/diagnóstico , Propofol/administração & dosagem , Fentanila/administração & dosagem , Monitorização Intraoperatória/estatística & dados numéricos , Anestésicos Intravenosos/administração & dosagem , Monitores de Consciência/normas , Hemodinâmica
2.
Rev. méd. Chile ; 138(3): 352-357, mar. 2010. tab
Artigo em Espanhol | LILACS | ID: lil-548173

RESUMO

Anesthesia awareness, or "unintended intra-operative awareness" occurs during general anesthesia, on the operating table, when a patient has not had enough general anesthetic or analgesic to prevent consciousness or waking up during surgery. According to international studies its global incidence ranges from 0.1 to 0.2 percent. Its impact on people can be as severe as other traumatic experiences such as natural disasters, violent fights or sexual abuse. The prevalence of symptoms compatible with post traumatic stress disorder can be as high as 50 percent, after experiencing the awareness phenomenon. This paper reviews the main issues of the awareness phenomenon.


Assuntos
Humanos , Anestesia Geral , Consciência no Peroperatório , Transtornos de Estresse Pós-Traumáticos/psicologia , Consciência no Peroperatório/diagnóstico , Consciência no Peroperatório/epidemiologia , Consciência no Peroperatório/psicologia , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA